Aiming at the vessel structure design of the 5900 electric arc furnace (EAF), this paper systematically compares a one-piece furnace shell solution with a split-type furnace shell solution that originates from an early Italian design circulating on the market. The one-piece solution was developed by RWOOL China and combines Russian EAF shell design philosophy with the electric furnace expertise accumulated over many years at Xiangtan Iron and Steel Works. It uses an integral cylindrical shell with an inner diameter of 2950 mm and a wall thickness of 22 mm, together with stiffening ribs covering the full shell wall (height > 2400 mm) and a 25-point annular support system (16 points on the outer ring plus 9 points on the inner ring), achieving structural optimisation through a multi-stage load-diffusion path of “2 columns → flat platform → H-beam grid → 25 support points”. The split-type solution derives from the design of the first EAF that an Italian company built in China about 15 years ago. It uses a two-section assembly with an upper section of 2850 mm inner diameter and a lower section of 3050 mm inner diameter, a wall thickness of only 16 mm, stiffening ribs covering only the working layer (about 1400 mm), and four columns of 400 × 600 mm cross-section supporting it directly from the ground.
Through an accurate calculation of the total vessel weight (149.0 t), including a detailed breakdown into the vessel and roof (30 t), the five-layer refractory system (67.5 t) and the melt (51.5 t); through hoop stress calculation based on thin-walled cylinder theory (1.64 MPa for the one-piece design versus 2.18 MPa for the split-type design, a reduction of 32.9%); through support-point load analysis (58.5 kN per point for the one-piece design versus 365.5 kN for the split-type design, a reduction of 84%); through a comparison of column cross-sectional area (8.0 m² versus 0.96 m²); and through a thermodynamic analysis of the freeze-lining protection mechanism, this paper comprehensively demonstrates, from the four dimensions of structural mechanics, thermodynamics, materials science and engineering practice, the significant advantages of the one-piece design in terms of safety, reliability, repairability and economy. This paper also draws on relevant domestic and international patents and academic literature as corroborating evidence, which confirms the validity and advanced nature of the integrated design approach.

1 Introduction
1.1 Research Background
The electric arc furnace (EAF) is a core piece of equipment in the modern metallurgical industry and is widely used in steelmaking, ferroalloy production, slag processing and non-ferrous metal smelting. Its basic working principle is to use the electric arc struck between the electrodes and the charge as a heat source, melting solid raw materials into a liquid, which is then refined and composition-adjusted to obtain a qualified product. In this process, the vessel is the key structure that directly carries the high-temperature melt (at temperatures above 2000 °C) and resists thermal stress, chemical attack and mechanical impact; the soundness of its design directly determines the safety, service life and productivity of the entire installation.
EAF vessel design involves the intersection of several engineering disciplines, including structural mechanics (shell strength and stiffness), thermodynamics (temperature field distribution and thermal stress), materials science (refractory selection and service life), fluid mechanics (melt hydrostatic pressure and flow) and manufacturing processes (welding, rolling, heat treatment). An excellent vessel design must find the best balance among these mutually constraining factors.
1.2 History of Technical Development
EAF vessel structure design has undergone a long technical evolution. Early EAF designs largely borrowed structural forms from blast furnaces and converters; the shell was welded from relatively thick steel plate, with emphasis on structural strength and relatively little attention paid to thermal stress and fatigue. As metallurgical processes advanced and requirements for equipment efficiency increased, vessel design gradually moved towards light weight, high efficiency and long service life.
In Europe, the split-type shell is a relatively traditional structural form. Such designs divide the shell into an upper and a lower section (sometimes even more sections) joined by flanges or welding. The advantage of the split-type design is ease of manufacture and transport — each shell section is smaller, so it can be fabricated separately in the workshop and then assembled on site. However, this design also brings a structural weakness that cannot be ignored: the joints between sections form structural discontinuities which, under long-term high-temperature operation and repeated thermal cycling, readily become sources of stress concentration and fatigue failure.
About 15 years ago, an Italian company built the first EAF in China using a split-type design. The design concept of that unit represented a relatively advanced engineering approach at the time, and its structural drawings subsequently circulated widely on the domestic market, becoming a “standard drawing” adopted by many manufacturers. Many manufacturers copied the design directly without in-depth analysis, so that a large number of EAFs on the domestic market now use the split-type structural solution that originates from the early Italian design. However, as operating time accumulated, this design revealed a series of structural problems in actual service, including cracking at the joints, uncontrolled shell deformation, refractory collapse and difficulty of repair after an incident.
1.3 The Innovative Approach of the One-Piece Design
In sharp contrast to the split-type design stands the one-piece shell design philosophy. Its core idea is to treat the shell as a complete load-bearing structure and, by eliminating joints, enhancing shell integrity and optimising the load transfer path, to achieve a fundamental shift from “segmented load bearing” to “integral load bearing”.
The one-piece shell design of RWOOL China combines three technical strands:
First, Russian EAF shell design philosophy. Russia has extensive engineering experience and distinctive design concepts in the field of electric arc furnaces and submerged arc furnaces. It places particular emphasis on the importance of a water-cooled shell, controlling shell temperature through a properly designed water-cooling system to extend shell life, and it also pays attention to the circular flange structure at the bottom of the vessel and to a uniformly distributed arrangement of support points. The RWOOL design draws fully on these concepts and adopts a concentric double-ring support system at the vessel bottom (16 outer points plus 9 inner points, 25 points in total, carrying the load uniformly).
Second, the electric furnace expertise accumulated at Xiangtan Iron and Steel Works (a former state-owned enterprise). As a large state-owned steel enterprise with decades of history, Xiangtan Iron and Steel Works has accumulated extensive practical experience in EAF operation and maintenance, covering refractory selection, cooling system optimisation, control of operating parameters, and fault prevention and handling. The RWOOL design reflects a deep understanding of this practical experience in the graded design of the refractory system and in freeze-lining temperature control.
Third, RWOOL’s own engineering innovation. Building on these two technical strands, a number of engineering innovations were made: a one-piece formed shell with a 22 mm wall thickness (37.5% thicker than the market solution), a stiffening rib system covering the full shell wall (height > 2400 mm, 1.7 times that of the market solution), and a multi-stage load-diffusion system of “2 columns → platform → H-beam grid → 25 support points”.
1.4 Scope and Methods of This Study
Taking the 5900 electric arc furnace as the research object, this paper combines theoretical analysis with numerical calculation to carry out a systematic comparative analysis of the one-piece and split-type solutions. The specific contents are: (1) a detailed description and comparison of the structural parameters of the two solutions; (2) an accurate calculation of the total vessel weight; (3) hoop stress calculation based on thin-walled cylinder theory; (4) support-point load analysis and load transfer path analysis; (5) comparison of column loads and cross-sectional areas; (6) thermodynamic analysis of the freeze-lining protection mechanism; (7) comparison of failure modes with verification from engineering practice; and (8) corroborating analysis drawing on domestic and international patents and academic literature.
2 Theoretical Basis and Design Philosophy of the One-Piece Shell Design
2.1 The Debate Between “Integral Load Bearing” and “Segmented Simplification”
In engineering design, two basic approaches are usually available for complex load-bearing structures. The “integral load bearing” concept holds that the best way for a structure to carry loads is to distribute and bear them as a whole, so the designer eliminates weak links (such as joints and fasteners) as far as possible and enhances structural continuity. The “segmented simplification” concept holds that breaking a complex structure into several simple units reduces manufacturing difficulty and facilitates on-site assembly, but it pays relatively little attention to the connections between those units.
For the special structure that is an EAF vessel, the “integral load bearing” concept is clearly superior. The reason is that the shell operates at extremely high temperatures (the inner wall can reach 1350–1400 °C), so any structural discontinuity becomes a source of stress concentration; repeated thermal cycling occurs in service (furnace on – furnace off – furnace on), and the joints are the positions most prone to fatigue cracking; the refractory material inside the shell expands at high temperature, and an integral annular shell can carry that pressure uniformly; and if leakage occurs, a one-piece shell can continue to operate until a scheduled shutdown and then be repaired locally.
2.2 Design Principles of the RWOOL Solution
Principle 1: structural continuity first. The entire shell is rolled from a single steel plate, with no joint anywhere from top to bottom. The 22 mm wall thickness not only provides a sufficient strength margin but also ensures uniformity and integrity of the shell under thermal expansion.
Principle 2: stiffness enhancement in all directions. The stiffening ribs cover the full height of the shell wall (> 2400 mm) rather than only the working layer, ensuring that the shell has sufficient hoop stiffness at every height to resist the radial pressure generated by refractory expansion.
Principle 3: multi-stage load diffusion. The load transfer path from the vessel to the ground passes through several stages of progressive diffusion, each of which further disperses the concentrated load, so that the load carried by the columns is finally distributed uniformly over their cross-section.
Principle 4: active temperature control. By precisely controlling the shell wall temperature within the range of 1375 ± 25 °C, a protective freeze lining is actively formed, using the solidification of the melt itself to protect the shell wall and the furnace bottom.
2.3 Comparison with Russian and European Design Concepts
Russia has a deep technical heritage in the design of electric arc furnaces and submerged arc furnaces, with particular emphasis on the importance of a water-cooled shell, the necessity of uniform support and structural redundancy. Research published by Liu et al. in Steel Research International found that thermal stress concentration and deformation of the vessel are the main causes of shell cracking, and that a rational arrangement of stiffening ribs can significantly reduce thermal stress concentration, thereby validating the scientific basis of full-wall stiffening from the perspective of numerical simulation.
3 Detailed Description of the Vessel Structure Design

Figure 1 Overall comparison of vessel structures: one-piece (RWOOL design) versus split-type (market solution)
3.1 One-Piece Shell Solution (RWOOL Design)
3.1.1 Main Shell Structure
The main body of the RWOOL shell is a complete cylindrical shell, rolled and welded from a single steel plate. Inner diameter D = 2950 mm, total vessel height H = 2880 mm, wall thickness t = 22 mm. The 22 mm wall is 37.5% thicker than the 16 mm of the market solution. This increase is not simply “adding material” but is based on detailed mechanical calculation and engineering experience: within the framework of thin-walled cylinder theory, hoop stress is inversely proportional to wall thickness (σ = P·R/t), and the 22 mm wall reduces hoop stress by 32.9%; a thicker wall means greater structural stiffness, so that under the combined action of thermal expansion and refractory expansion the shell deforms less and more uniformly; and the 22 mm wall also provides a larger corrosion allowance, so that even if the inner surface becomes thinner through oxidation at high temperature, sufficient thickness remains to guarantee structural safety.
3.1.2 Stiffening Rib System
In the RWOOL solution, stiffening ribs are arranged uniformly around the circumference of the outer shell wall and cover more than the full height of that wall (> 2400 mm). The ribs are made of 15–20 mm thick steel plate with a protruding height of about 60 mm and are fully welded to the outer shell wall, forming a “stiffened cylindrical shell” that acts as an integral load-bearing structure. About 26 ribs are distributed uniformly around the circumference at a spacing of about 350 mm. The main function of the ribs is to increase the hoop stiffness and bending stiffness of the shell, effectively limiting radial deformation and preventing the shell from “bulging”. Full-wall ribs also provide uniform axial support for the shell, preventing axial buckling instability.
Compared with the market solution, whose ribs cover only the working layer (about 1400 mm), the RWOOL ribs weigh about 600 kg in total, 2.1 times the market solution (about 288 kg). This “extra” weight buys stiffness enhancement for the shell in all directions.
3.1.3 Furnace Bottom Structure
The RWOOL vessel bottom uses a distinctive “split cone” design. The bottom face is circular and flat, and the side is a conical surface rising from the edge of the bottom face, blending smoothly into the lower edge of the shell wall. The 25 support points are located directly below the vertical face of the shell wall; the 16 outer points are distributed uniformly on an outer ring and the 9 inner points on an inner ring, forming an integral frame through a bottom beam structure. This “double ring plus cross beam” support structure ensures that the load on the vessel bottom is transferred uniformly in any direction.

Figure 3 Comparison of the vessel base and support point arrangement (left: RWOOL, 16 outer points plus 9 inner points; right: market solution, 4 points)
3.1.4 Support and Load Transfer System
The support and load transfer system is one of the highlights of the RWOOL design. The complete load transfer path passes through five stages of diffusion: stage one, vessel → 25 support points, 58.5 kN (6.0 t-force) per point; stage two, support points → H-beam grid, with parallel H-beams forming a uniform load-bearing plane that disperses the 25 concentrated loads into an approximately uniformly distributed surface load; stage three, H-beam grid → concrete flat platform, with a platform thickness of about 1 m, converting the concentrated loads into a surface load; stage four, platform → 2 columns (cross-section 4 m × 1 m), each column carrying 74.5 t-force with a compressive stress of only 0.183 MPa, far below the compressive strength of concrete (usually > 20 MPa); stage five, columns → foundation, with a pressure on the foundation of only about 36.6 kPa.
The core advantage of this five-stage diffusion system is that each stage further disperses the concentrated force, so that the pressure finally borne by the foundation is extremely small. More importantly, the flat platform, as the key stage, converts the 25 concentrated loads from the superstructure into a uniform surface load, eliminating any possibility of local stress concentration.
3.1.5 Cooling System
The RWOOL cooling system is divided into an upper water-cooled part and a lower air-cooled part. The upper part uses water-cooling pipes or a water jacket on the outer shell wall to keep the shell temperature within a reasonable range; the lower part uses forced convective air cooling of the outer shell wall, avoiding the risk of water leakage that water cooling can bring.
3.2 Split-Type Shell Solution (Market Solution)
The market solution divides the shell into two sections: the upper section has an inner diameter of 2850 mm and a height of 1957 mm, and the lower section has an inner diameter of 3050 mm and a height of 1156 mm. The shell wall is uniformly 16 mm thick. There is an abrupt change of diameter at the connection between the two sections (jumping from 2850 mm to 3050 mm), creating the weakest link in the structure. The stiffening ribs cover only the working layer region (about 1400 mm in height), and the upper part, about 1500 mm, has no rib stiffness support.
The support structure consists of four columns of 400 × 600 mm cross-section (only 0.24 m² each), extending from the ground to the bottom of the vessel. The total cross-sectional area of the four columns is only 0.96 m². At a height of 3 m, a ring beam of 250 × 300 mm cross-section connects the four columns. The four support points directly carry the vessel load, each point carrying 365.5 kN (37.3 t-force), 6.2 times that of the RWOOL solution. The compressive stress in the columns reaches 1.523 MPa, 8.3 times that of the RWOOL solution (0.183 MPa).

Figure 2 Comparison of shell body cross-sections (left: one-piece Ø2950 mm / wall thickness 22 mm; right: split-type Ø2850 + Ø3050 mm / wall thickness 16 mm)
4 Accurate Calculation of Weight and Volume
4.1 General Calculation Rules
The total weight of an EAF vessel consists of four parts: the shell (including the roof), the refractory material, the melt in the furnace and accessories. The total weight is the core input parameter for the design of the support structure.
4.2 Weight of Vessel and Roof
The RWOOL vessel shell (including the roof) weighs about 30 t in total, comprising the cylindrical shell wall (rolled from 22 mm steel plate), the roof cover, the stiffening rib system (about 600 kg), the cooling pipes and accessories, and reinforcement around openings such as the tapping hole and the observation port. The market solution’s shell weighs about 25 t (including about 288 kg of ribs); because the wall is thinner and there is no complete rib system, it is slightly lighter overall. However, under the high-temperature, heavy-load conditions of an electric arc furnace, adequate structural mass is precisely what guarantees safe operation.
4.3 Weight of Refractory Material
Refractory material accounts for the largest share of the weight of an EAF vessel. The RWOOL solution uses a five-layer graded refractory system:
| Layer | Material | Density (g/cm³) | Weight (t) | Function |
| Layer 1 | Insulation layer | ~1.0 | 0.5 | Thermal insulation; protects the shell |
| Layer 2 | Transition layer | ~2.5 | 30 | Buffers thermal stress; accommodates differential expansion |
| Layer 3 | Working layer (MgO) | ~3.0 | 25 | Direct contact with the melt; erosion resistant |
| Layer 4 | Reinforcing layer | ~2.0 | 5 | Structural reinforcement; prevents spalling |
| Layer 5 | Inner lining layer | ~2.8 | 7 | Scour resistant; protects the working layer |
| Total | 67.5 |
The five-layer refractory totals 67.5 t, accounting for 45.3% of the total vessel weight. This proportion reflects the central role of refractory material in EAF design.

Figure 4 Comparison of the five-layer graded refractory lining structure
4.4 Weight of the Melt
Melt weight calculation: bath diameter D = 5.4 m, bath height h = 0.9 m, melt density ρ = 2.5 t/m³.
V = π × r² × h = π × 2.7² × 0.9 = π × 7.29 × 0.9 = π × 6.561 = 20.61 m³
W = V × ρ = 20.61 × 2.5 = 51.5 t
4.5 Summary of Total Weight
| Component | Weight (t) | Share |
| Vessel + roof (including stiffening ribs) | 30.0 | 20.1% |
| Refractory material (5 layers) | 67.5 | 45.3% |
| Melt | 51.5 | 34.6% |
| Total | 149.0 | 100% |
The total vessel weight is 149.0 t and is transferred to the ground through the support structure. How to transfer this 149 t load safely, uniformly and reliably to the foundation is the core issue in the design of the support structure.
5 Structural Mechanics Analysis
5.1 Hoop Stress Analysis of the Shell Wall
The main mechanical loads borne by an EAF shell are the hydrostatic pressure of the melt inside the furnace, the radial pressure generated by thermal expansion of the refractory material, and the thermal stress caused by the temperature difference across the shell wall. This section uses classical thin-walled cylinder theory to calculate the hoop stress.
5.1.1 Hydrostatic Pressure Calculation
The maximum hydrostatic pressure exerted by the melt on the shell wall (at the bottom of the wall):
P = ρ·g·h = 2500 × 9.81 × 1.0 = 24,525 Pa ≈ 24.52 kPa
5.1.2 Hoop Stress Calculation
According to thin-walled cylinder theory (the condition D/t > 20 is satisfied), the hoop stress formula is:
σ_θ = P·R / t
RWOOL solution (one-piece):
σ_ours = 24,525 × 1.475 / 0.022 = 1,644,273 Pa ≈ 1.64 MPa
Market solution (split-type, upper section):
σ_mkt = 24,525 × 1.425 / 0.016 = 2,184,250 Pa ≈ 2.18 MPa
Stress ratio: σ_mkt / σ_ours = 2.18 / 1.64 = 1.33
5.1.3 Analysis and Discussion
The hoop stress in the shell wall of the market solution is 33% higher than that of the RWOOL solution. Although the upper section of the market solution has a slightly smaller inner diameter (2850 versus 2950 mm), the advantage of its smaller radius is completely cancelled out and exceeded by the disadvantage of its significantly thinner wall.
From the standpoint of mechanics of materials, lower hoop stress means: (1) the thermally-mechanically coupled stress in the shell at the same temperature is smaller, giving a higher safety margin; (2) the elastic deformation of the shell is smaller, which helps maintain the geometric stability of the vessel; and (3) the fatigue life of the shell is longer (fatigue life is inversely proportional to a power of the stress amplitude).
It should be noted that the above calculation considers only hydrostatic pressure. In actual operation, the refractory expansion pressure may reach several hundred kPa and the thermal stress is also considerable. However, whatever the magnitude of the additional stresses, the ratio between the stresses of the two solutions does not change, because that ratio depends only on the ratio of R/t.
5.2 Support-Point Load Analysis
RWOOL solution (25 support points): F_ours = 149.0 × 9.81 / 25 = 58.5 kN ≈ 6.0 t-force
Market solution (4 support points): F_mkt = 149.0 × 9.81 / 4 = 365.5 kN ≈ 37.3 t-force
Load ratio: F_mkt / F_ours = 6.2. The load carried by each support point in the market solution is 6.2 times that in the RWOOL solution, imposing extremely demanding requirements on the local strength, stiffness and fatigue life of the support structure.

Figure 5 Comparison of the plan arrangement of vessel support points (left: 25-point double-ring support; right: 4-point X-type support)
5.3 Comparison of Column Loads and Cross-Sectional Areas
| Parameter | RWOOL solution | Market solution |
| Number of columns | 2 | 4 |
| Cross-section per column | 4m × 1m = 4.0 m² | 0.4m × 0.6m = 0.24 m² |
| Total cross-sectional area | 8.0 m² | 0.96 m² |
| Load per column | 74.5 t-force | 37.3 t-force |
| Compressive stress in columns | 0.183 MPa | 1.523 MPa |
Although each column in the RWOOL solution carries a larger absolute load (74.5 versus 37.3 t-force), the actual compressive stress is lower (0.183 versus 1.523 MPa) and the safety margin is higher, because the cross-sectional area is far larger than in the market solution (4.0 versus 0.24 m²). More importantly, the RWOOL solution places a flat platform and an H-beam grid above the columns as load diffusion layers, effectively eliminating any possibility of local stress concentration.

Figure 6 RWOOL concrete platform foundation (load capacity 180 t, laid over 20# I-beams, with twin columns)

Figure 7 Market solution with four independent concrete foundations for the columns
6 Thermodynamic Analysis: The Freeze-Lining Protection Mechanism
6.1 Principle of the Freeze Lining
Freeze-lining technology (also known as “self-protecting lining” technology) is an advanced EAF design concept. Its basic principle is that, by properly controlling the temperature field in the shell wall region, a protective layer of solidified melt is formed on the inner surface of the wall. This solidified material separates the high-temperature melt from the refractory material, thereby greatly slowing chemical erosion and mechanical scour and significantly extending lining life.
The theoretical basis of freeze-lining technology can be traced back to long-standing practice in the blast furnace and submerged arc furnace fields. In blast furnace smelting, the “slag skull” formed on the inner surface of the furnace wall is a natural freeze-lining protection layer. Research shows that, under a suitable temperature gradient, the thickness of the freeze lining can self-stabilise: when the heat flux increases, part of the inner surface of the freeze lining melts and thins, thermal resistance decreases and heat dissipation increases, until the freeze lining finally returns to its equilibrium thickness.
6.2 Temperature Control Strategy of the RWOOL Solution
The RWOOL solution precisely controls the shell wall temperature within the range of 1375 ± 25 °C (that is, 1350–1400 °C). This temperature range was chosen on the basis of the following analysis:
(1) Minimisation of refractory corrosion. The chemical erosion rate of magnesia refractory (MgO-based) increases sharply with temperature at high temperature. Controlling the shell wall temperature at around 1375 °C keeps the chemical erosion rate of the working layer at a low level.
(2) Stable formation of the freeze lining. The temperature in the arc core region exceeds 2000 °C; with a wall temperature of 1375 °C, a sufficient temperature gradient is established between the inner surface of the wall and the high-temperature melt, so that the melt cools and solidifies rapidly near the wall surface, forming a stable protective freeze lining (typically 40–100 mm thick).
(3) Sustainability of “protecting the furnace with slag”. The freeze lining is continuously eroded and regenerated during operation, forming a dynamic equilibrium. As long as the temperature is properly controlled, the freeze lining persists stably, realising a virtuous cycle of “protecting the furnace with slag” and greatly reducing the rate of refractory consumption.
6.3 Temperature Control Dilemma of the Split-Type Solution
Owing to inherent structural deficiencies, the split-type solution faces more challenges in temperature control: the structural discontinuity at the joint between the upper and lower sections leads to non-uniform heat conduction, and the joint region is prone to local overheating or undercooling; the difference between water cooling in the upper section and air cooling in the lower section produces additional temperature gradients and thermal stress at the joint; and the thin 16 mm wall conducts heat faster, so the outer wall temperature is higher and the thermal load on the cooling system is greater. These factors make it difficult for the split-type solution to form a uniform, stable freeze lining.
7 Failure Modes and Verification from Engineering Practice
7.1 Fault Tolerance of the One-Piece Solution
One of the most prominent advantages of the one-piece shell is its excellent fault tolerance. Under normal operating conditions the shell “grows fatter” uniformly under thermal expansion (radial expansion of about 35 mm), and the 22 mm wall thickness together with full-wall stiffening ribs provides sufficient hoop restraint. When refractory expansion is abnormal, the 100 mm insulation layer provides buffer space, and the uniform annular restraint mechanism of the one-piece shell distributes the expansion force evenly. When the outer shell leaks, the situation can be handled by reducing output → freezing at the leak location → local repair → resuming production, without a complete shutdown.
7.2 Failure Modes of the Split-Type Solution
The failure mode of the split-type shell has the typical character of a chain reaction and proceeds in five stages:
Stage one: stress concentration at the joint. At the interface between the upper and lower sections (at a height of about 1.2 m) there are two 90° bends, forming structural discontinuities. Under long-term high-temperature operation and repeated thermal cycling, plastic deformation gradually accumulates at the interface.
Stage two: cracking of the joint. The accumulated deformation drives the stress beyond the yield strength of the material and cracks initiate. Cracks usually start at the inner corner of the bend and propagate along the weld or the heat-affected zone.
Stage three: uncontrolled shell deformation. After the joint cracks, the shell loses structural continuity and deformation of the upper and lower sections is no longer compatible. The temperature difference between the water-cooled upper section and the air-cooled lower section further aggravates the non-uniformity of deformation.
Stage four: refractory collapse. Once shell deformation is out of control, the refractory loses its restraint, begins to loosen and spall, and the high-temperature melt comes into direct contact with the shell, causing it to burn through.
Stage five: complete shutdown. The damaged shell must be dismantled, the refractory replaced and the shell re-welded, which takes a long time and is costly.
7.3 Verification by Engineering Cases
In actual engineering, EAFs using the split-type solution have already exhibited the failure modes described above. Several EAF operating units have reported cracking at shell joints and refractory collapse, which agrees fully with the theoretical analysis in this paper. By contrast, operating records for EAFs using the one-piece solution show that, although uniform thermal expansion of the shell occurs, joint cracking and structural collapse have never been observed.
8 Corroborating Analysis: Support from Domestic and International Patents and Literature
8.1 Russian EAF Technology Patents
Russian patent CN1290336A describes a cooled furnace roof design for electric arc furnaces and ladle furnaces and emphasises the central role of the cooling system in EAF design. This patent is highly consistent with the combined water-cooling/air-cooling strategy of the RWOOL solution. Russian submerged arc furnace designs pay particular attention to the structural integrity of the shell, usually adopting integral rolling, leaving a sufficient corrosion allowance in the wall thickness, and covering the full height of the shell wall with stiffening ribs.
8.2 European Multiphysics Coupling Research
The multiphysics coupling model for submerged arc furnaces published by Liu et al. in Steel Research International used the finite element method to simulate the thermal–structural coupling behaviour of a submerged arc furnace. The study found that: (1) thermal stress concentration and deformation of the vessel are the main causes of shell cracking; (2) a rational arrangement of stiffening ribs can significantly reduce thermal stress concentration; and (3) increasing the shell wall thickness has a significant effect in reducing thermal stress. These conclusions validate the scientific basis of the RWOOL design from the perspective of numerical simulation.
8.3 Chinese Research on Titanium Slag Melting-Separation Electric Furnaces
A study on the lining structure design of titanium slag melting-separation electric furnaces published in the journal Iron Steel Vanadium Titanium compared two design solutions, namely an insulating lining and a freeze lining. The study showed that, although the freeze lining increases heat loss by about 2.4%, its protective effect greatly extends lining life and significantly reduces maintenance costs and shutdown losses. This conclusion directly supports the validity of the “freeze-lining protection” design concept of the RWOOL solution.
8.4 Patents on EAF Shell Structure Optimisation
US Patent 5,561,685 of UCAR Carbon Technology Corporation describes a modular spray-cooled side-wall design and places particular emphasis on the importance of cooling uniformity, pointing out that non-uniform cooling leads to thermal stress concentration and deformation of the shell. US Patent 5,717,798 of ABB describes an EAF design with reduced vessel cooling that lowers cooling energy consumption by optimising cooling water flow rate and temperature distribution. These international patents confirm, from different angles, the importance of temperature control and structural integrity in EAF shell design.
8.5 Domestic Engineering Practice
Patent CN223592750U of Zhongye Nanfang Engineering Technology Co., Ltd. describes a separated rotary electric arc furnace design, and patent CN107653355B of MCC Jingcheng Engineering Technology Co., Ltd. describes a rotatable EAF bottom design. These research results from domestic metallurgical engineering design institutes show that optimising the design of the EAF bottom support structure is an important direction in the development of EAF technology in China. The innovations of the RWOOL solution in the bottom support system (25-point annular support plus multi-stage load diffusion) are a typical representative of this technical trend.
9 Comprehensive Discussion
9.1 The Essential Difference in Design Philosophy
The RWOOL solution adopts the “integral load bearing” concept and treats the vessel as an indivisible, complete structural system. Every design decision serves the core objective of “integrity”: the one-piece formed shell ensures that there is no structural weak point; full-wall stiffening ribs ensure stiffness in all directions; 25 uniformly distributed support points ensure uniform load carrying; the multi-stage load diffusion path ensures that the load is dispersed stage by stage; and the precise temperature control strategy ensures that the freeze lining forms stably. These design elements work together in a coordinated way, forming a complete and self-consistent structural system.
The market solution adopts the “segmented simplification” concept and breaks the vessel down into several independent units. This design reduces manufacturing difficulty but sacrifices structural integrity. Stress concentration at the section joints, high hoop stress in the thin-walled shell, locally applied stiffening ribs and concentrated four-point support mean that this solution is prone to a variety of structural problems in long-term operation.
9.2 A Dialectical Understanding of “Deformation ≠ Failure”
The most common misunderstanding of the one-piece solution on the market is: “a one-piece shell deforms (grows fatter), which shows that there is a problem with the design”. This view confuses the concepts of “deformation” and “failure”. In structural mechanics, every load-bearing structure deforms under the action of external forces. What matters is not whether it deforms, but the nature of the deformation: is it uniform, recoverable elastic deformation, or local, non-recoverable plastic deformation? Is it integral, controllable deformation, or concentrated, runaway deformation?
The one-piece shell of the RWOOL solution “grows fatter” uniformly under thermal expansion, and this is uniform, predictable thermoelastic deformation. The 22 mm wall thickness and the full-wall stiffening ribs ensure that this deformation remains within the elastic range and does not cause structural damage. More importantly, this uniform deformation is precisely what proves the integrity of the shell — the whole shell expands uniformly as one body, with no local weak point.
By contrast, the illusion that the split-type shell “does not deform” precisely conceals its structural weakness. In the early period of operation, the split-type shell does indeed show no obvious deformation, but this is because the stiffness at the joint is temporarily sufficient. As operating time increases, stress concentration and fatigue accumulation at the joint gradually intensify, eventually leading to runaway local deformation and structural collapse. Looking back at that point, “no deformation” was only a temporary illusion, while “collapse” was the inevitable outcome.
9.3 Life-Cycle Economic Analysis
From the perspective of life-cycle cost, the economic advantages of the one-piece solution are equally significant: (1) longer lining life — the freeze-lining protection mechanism greatly reduces the rate of refractory consumption and extends the lining replacement interval; (2) lower maintenance costs — local repair versus full shutdown and major overhaul, a difference of several times in maintenance cost; (3) higher equipment availability — fewer shutdowns for maintenance and shorter maintenance time, increasing effective production time; and (4) better product quality — a stable furnace condition and stable temperature control favour a product of uniform composition.
Although the initial investment of the one-piece solution (30% greater shell weight and 110% greater rib weight) is higher than that of the split-type solution, taking into account life-cycle operating costs, maintenance costs and shutdown losses, the total cost of the one-piece solution is far lower than that of the split-type solution.
10 Conclusions
Through a systematic comparative analysis of one-piece and split-type shell solutions for the 5900 electric arc furnace, and from the perspectives of design philosophy, structural mechanics, thermodynamics, materials science and engineering practice, this paper draws the following main conclusions:
(1) Hoop stress advantage: the hoop stress in the shell wall of the one-piece solution (22 mm wall thickness) is 1.64 MPa, 32.9% lower than the 2.18 MPa of the split-type solution (16 mm wall thickness), giving a higher structural safety margin. This advantage stems from the reduction in the R/t ratio brought about by the greater wall thickness and is a direct manifestation of basic structural mechanics.
(2) Stiffening rib stiffness advantage: the stiffening ribs of the one-piece solution cover the full height of the shell wall (> 2400 mm) and weigh about 2.1 times those of the split-type solution (about 1400 mm), providing the shell with stiffness enhancement in all directions, both hoop stiffness and bending stiffness.
(3) Support structure advantage: the one-piece solution uses 25 support points and, through the multi-stage load-diffusion system of “2 columns → platform → H-beam grid → 25 points”, the load per point is only 58.5 kN (6.0 t-force); the split-type solution uses only 4 support points, with a load per point as high as 365.5 kN (37.3 t-force), 6.2 times that of the one-piece design.
(4) Structural integrity advantage: the uniform annular load-carrying mechanism of the one-piece shell means that expansion is borne by the entire vessel, and even a local leak can be tolerated in operation and repaired locally; the split-type shell suffers stress concentration at the joint, and cases of joint collapse have already occurred in actual engineering.
(5) Freeze-lining protection advantage: by precisely controlling the shell wall temperature within the range of 1375 ± 25 °C, the one-piece solution forms a stable protective freeze lining that effectively protects the shell wall and the furnace bottom. This design is supported theoretically by a number of domestic and international studies.
(6) Repairability and economic advantages: after an incident, the one-piece solution can be repaired locally and put back into production quickly, whereas the split-type solution requires a complete shutdown and major overhaul. From a life-cycle cost perspective, the one-piece solution has significant economic advantages.
Summary: the one-piece shell design is significantly superior to the split-type solution in terms of structural safety, operational reliability and repairability. The misunderstanding of the one-piece solution on the market — “a one-piece shell deforms” — precisely overlooks one basic fact: the uniform deformation (“growing fatter”) of a one-piece shell is a manifestation of structural integrity and shows that the design is successful. Deformation does not affect production, and the repair period is short; whereas once a split-type furnace suffers a side leak or deformation, the shell cannot withstand it and production must be stopped completely. This core difference is the fundamental advantage of the one-piece shell design.